NEMA G10 has high flexural, impact, and bond strength at room temperatures. It retains good electrical properties under dry and humid conditions. It is used in the electrical industry and anywhere a high strength electrical insulator in humid or dry conditions is needed.
   

 

An electrical/mechanical grade of glass cloth laminate impregnated and cured with a non-brominated epoxy resin.

Sheet sizes 36 x 48, 48 x 48, 48 x 96, and 48 x 108 in thicknesses .031 in. to 5 in.; cut and fabricated per drawing .

Natural

 

Density

119 lbs/ft3 - .069 lbs/in3

Maximum operating temperature

 

  electrical

266° F (130° C)

  mechanical

284° F (140° C)

Water absorption

0.05%

Hardness (Rockwell M)

109

Compressive strength

60,000 psi

Tensile strength

50,000 psi

Flexural strength

65,000 psi

Impact strength - Izod edgewise with grain

12.0 ft-lb/in

Dielectric strength

550 vpm

Dielectric constant (@ 106 cycles per second)

5.0

Volume resistivity

6 x 106 megohm-cm

Arc resistance

100 sec

Surface resistivity

1 x 106 megohms

Parallel dielectric

60 kv

E-mail this page to a colleague